Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
Eur J Ophthalmol ; : 11206721241246816, 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38602030

RESUMO

PURPOSE: To report a case of phacolytic glaucoma with atypical presentation in a patient which was diagnosed with biometry swept source optical coherence tomography (SS-OCT) and anterior segment spectral domain OCT (SD-OCT). METHODS: A 56-year-old male with a history of cytomegalovirus (CMV) chronic anterior uveitis in the right eye presented with a white cataract, minimal anterior chamber reaction and intraocular pressure (IOP) of 56 mmHg. Visual acuity was light perception. The anterior chamber was deep, without evidence of macroscopically visible capsular rupture. A surgical intervention was necessitated with the puzzle being whether to proceed with a trabeculectomy or a combined phaco-trabeculectomy. After a routine preoperative assessment with intraocular lens Master700, the disintegration of the natural lens was noticed. Anterior segment Spectralis OCT confirmed a lamellar separation of the anterior one third of the lens, resembling a poultaceous material. After an uneventful phacoemulsification, visual acuity was 6/6, IOP was well-controlled on maximum topical antiglaucoma treatment and no CMV recurrence was observed. RESULTS: The diagnosis of phacolytic glaucoma was established with the aid of current imaging OCT systems. Both OCT images were suggestive of a phacolytic nature of our case, despite the fact that the clinical presentation was not in concordance with such a typical case. In view of our findings the decision was to proceed with cataract extraction alone. CONCLUSION: This is the first time that we image and document the phacolytic nature of a natural lens. Our patient did not have the typical clinical presentation and was differentially diagnosed with biometry SS-OCT and confirmed by anterior segment SD-OCT.

2.
Case Rep Ophthalmol ; 15(1): 358-368, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38628308

RESUMO

Introduction: Retinal folds (RFs) may develop following rhegmatogenous retinal detachment (RRD) repair, though it consists an uncommon complication. Case Presentation: Herein, we present a case of late-onset postoperative outer RFs with aggravating characteristics following vitrectomy with silicone oil (SO) tamponade for RRD repair; early clinical findings, complications, anatomical and functional status during a 12-month follow-up period are described. Retinal imaging by acquiring optical coherence tomography scans and angiograms indicates detailed morphological and angiographic characteristics of the evolution of RFs over time. Our case provides insight into a combination of various types of RFs along with retinal disorganization with appearance in the late postoperative period after RRD repair with SO tamponade. Conclusion: Our aim was to raise awareness of the pathological processes that may be associated with the development and evolution of RFs after successful RRD repair, indicating that it is critical to accurately diagnose the type of RFs and closely monitor their progression in an attempt to provide prognostication for future visual outcomes.

3.
Cornea ; 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38478761

RESUMO

PURPOSE: The purpose of this study was to investigate the associations between central corneal endothelial cell density (ECD), endothelial morphology, and corneal thickness (central corneal thickness) with the anterior chamber depth, corneal volume (CV), white-to-white (WTW) distance, mean anterior chamber angle (CAmean), and gender in healthy individuals. METHODS: This observational study included 136 healthy volunteers. The ECD, coefficient of variation of cell area, and hexagonal cell appearance ratio (%Hex) were measured by means of specular microscopy. The central corneal thickness, anterior chamber depth, CV, WTW distance, and the angle width of 12 points were taken by the Pentacam HR Scheimpflug anterior segment imaging. The arithmetical mean of the 12 points was considered as the CAmean. We used mixed effect linear regression model for the statistical analysis of the data. RESULTS: ECD was positively correlated with CV (P = 0.028), while after adjusting for age, it was negatively correlated with age (P < 0.001). Coefficient of variation of cell area was positively correlated with CAmean (P = 0.036), while after adjusting for age, it was positively correlated with age (P < 0.001) and CAmean (P = 0.005). Hex was negatively correlated with WTW (P = 0.023) and CAmean (P = 0.025), and after adjusting for age, this correlation remained the same (P = 0.029 when correlated with WTW and P = 0.035 with CAmean). CONCLUSIONS: There were significant changes in the morphology of the corneal endothelial cells in eyes with wider anterior chamber angle. Greater pleomorphism and polymegethism of the corneal endothelium was observed in healthy patients with wider CAmean. Deepening of the anterior chamber as myopia progresses could render the corneal endothelium more fragile and susceptible to mechanical stress, which is an area worthy of further study.

4.
Ther Adv Ophthalmol ; 16: 25158414241232261, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38406626

RESUMO

X-linked retinoschisis (XLRS) is an inherited retinal degeneration affecting males, characterized by splitting of the retinal layers. We herein present the outcomes of surgical treatment in a case of XLRS complicated by rhegmatogenous retinal detachment (RRD). A 22-year-old male presented to the emergency department due to decreased visual acuity and visual field defect in his left eye Oculus Sinister (OS) of 1 week duration. The patient reported an early onset retinal degeneration and decreased visual acuity in both eyes since childhood in his past ocular history. Upon presentation, best corrected visual acuity (BCVA) was 6/30 on the right eye Oculus Dexter (OD) and 6/120 OS. Fundus examination revealed areas of peripheral retinal schisis, and the characteristic spoke wheel pattern on the macula of both eyes. In OS, a temporal RRD involving the macula was identified. The patient underwent surgical treatment with pars plana vitrectomy with internal limiting membrane (ILM) peeling, endolaser, and silicone oil (SO) tamponade. BCVA in OS improved to 6/60 and schistic cavities resolution was observed in the immediate postoperative period. The patient's BCVA further improved to 6/19 at 1 month, as foveal anatomy showed relative improvement. However, there was a rapid reappearance of schisis spaces in the macular area at this point, which was also followed by progressive deterioration of foveal schisis by 3 months post-operatively. The resorption and recurrence of lamellar macular schisis changes after ILM peel and presence of SO, highlights that although XLRS findings can temporarily improve upon surgical intervention, the pathogenetic mechanisms contributing to disease phenotype remain to be elucidated.

5.
Neurol Sci ; 2024 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-38191765

RESUMO

BACKGROUND: The TsiogkaSpaeth (TS) grid is a new, low-cost, and easy to access portable test for visual field (VF) screening which could be used by clinicians in everyday clinical practice. Our study aimed to determine the validity of an innovative screening grid test for identifying neurological disease-associated VF defects. METHODS: We enrolled two groups of participants: We assessed the one eye of ten consecutive adult patients with different types of neurological disease associated VF defects and ten eyes of controls in each group. The TS grid test was performed in each group. Sensitivity, specificity, and positive and negative predictive values of the TS grid scotoma area were assessed using the 24-2 VF Humphrey field analyzer (HFA) as the reference standard. RESULTS: Sensitivity and specificity of the TS grid test were 100% and 90.91%, respectively. The area under curve was 0.9545 with 95% CI 0.87-1.00. There was a significant correlation between the number of missed locations on the TS grid test and the visual field index of the HFA 24-2 (r = 0.9436, P < .0001). CONCLUSION: The sensitivity and specificity of the TS grid test were high in detecting VF defects in neurological disease. The TS grid test appears to be a reliable, low-cost, and easily accessed alternative to traditional VF tests in diagnosing typical neurological patterns of visual field defects. It would be useful in screening subjects for neurologically derived ocular morbidity in everyday clinical practice and in remote areas deprived of specialized health care services.

6.
BMC Ophthalmol ; 23(1): 359, 2023 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-37587408

RESUMO

BACKGROUND: Hydrophilic intraocular lens opacification is a rare complication due to calcification. With current new surgical techniques, including lamellar endothelial keratoplasty and vitrectomies, this irreversible complication is becoming more common. In this case study, we present clinical and laboratory features of a case of Carlevale hydrophilic acrylic IOL calcification. CASE PRESENTATION: Observational case report of a single incident case. An 83-year-old man was referred to our ophthalmic department complaining of right eye vision blurring for six months. Slit-lamp biomicroscopy revealed IOL opacification. Deposits of calcium phosphate were found both on the IOL's surface and inside it, according to thorough investigation using optical, scanning electron microscopy (SEM), and energy-dispersive X-ray (EDX) spectrometry. CONCLUSIONS: To the best of our knowledge, this is the first case to describe the laboratory evidence of Carlevale hydrophilic IOL calcification, suggesting possible explanation mechanisms based on underlying pathology and surgical technique. It reminds us that these findings suggest that physicians should be aware of possible hydrophilic IOL calcification.


Assuntos
Linfoma Intraocular , Lentes Intraoculares , Masculino , Humanos , Idoso de 80 Anos ou mais , Olho Artificial , Lentes Intraoculares/efeitos adversos , Esclera/cirurgia , Remoção de Dispositivo , Conscientização
7.
Ophthalmol Glaucoma ; 6(6): 657-667, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37321374

RESUMO

PURPOSE: To examine the generalizability, discuss limitations, and critically appraise recommendations on the management of primary angle-closure suspects (PACSs) that emerged as a result of recent randomized clinical trials challenging the widely accepted clinical practice of offering laser peripheral iridotomy (LPI) to PACS patients. To synthetize findings from these and other studies. DESIGN: Narrative review. SUBJECTS: Patients classified as PACS. METHODS: The Zhongshan Angle-Closure Prevention (ZAP)-Trial and the Singapore Asymptomatic Narrow Angle Laser Iridotomy Study (ANA-LIS) along with accompanying publications were reviewed. Epidemiologic studies reporting on the prevalence of primary angle-closure glaucoma and other precursor forms of the disease were also analyzed along with publications reporting on the natural course of the disease or studies reporting on outcomes after prophylactic LPI. MAIN OUTCOME MEASURES: Incidence of progression to more severe forms of angle closure. RESULTS: Patients recruited in recent randomized clinical trials are asymptomatic, do not have cataracts, may be younger, and have, on average, deeper anterior chambers depth compared with patients treated with LPI in clinics. CONCLUSIONS: The ZAP-Trial and ANA-LIS clearly represent the best available data on PACS management, additional parameters however may need to be considered when physicians face patients in clinic. PACS patients encountered at tertiary referral centers may represent more advanced cases with respect to ocular biometric parameters and may be at higher risk for disease progression compared with those recruited through population-based screening. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Assuntos
Glaucoma de Ângulo Fechado , Iris , Humanos , Iris/cirurgia , Pressão Intraocular , Glaucoma de Ângulo Fechado/cirurgia , Glaucoma de Ângulo Fechado/diagnóstico , Procedimentos Cirúrgicos Oftalmológicos , Lasers
8.
Case Rep Ophthalmol ; 14(1): 229-233, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37383169

RESUMO

Dexamethasone intravitreal implant (Ozurdex®; Allergan, Inc., CA, USA) has been proved to be effective in a variety of clinical settings including cases of pseudophakic cystoid macular edema. Uncommonly, this implant can migrate from the vitreous cavity and into the anterior chamber, especially in vitrectomized eyes with lens capsule defects. We report herein a rare case of anterior chamber migration and illustrate the passageway of the dexamethasone intravitreal implant through a new type of scleral fixated lens, the Carlevale IOL (Soleko-Italy). A 78-year-old woman was left aphakic following a complicated right eye hypermature cataract surgery with posterior capsule rupture and zonular dehiscence. Shortly thereafter, she underwent a planned combined pars plana vitrectomy with the placement of a Carlevale sutureless scleral fixated intraocular lens for the treatment of her aphakia. Due to a subsequent persistent cystoid macular edema that was unresponsive to topical treatment and sub-tenon corticosteroids, an intravitreal dexamethasone implant was injected. Eleven days after implantation, the patient presented with a floating implant in the anterior chamber and corneal edema. Following an immediate surgical removal, corneal edema resolved and visual acuity improved. One year later, results remain stable without macular edema recurrence. Anterior chamber migration of the Ozurdex implant is a potential complication in vitrectomized eyes, even when new types which are larger and specially designed for scleral fixation intraocular lenses are utilized. Corneal complications can be reversible following an immediate removal of the implant.

9.
J. optom. (Internet) ; 16(2): 128-134, Abr-Jun 2023. tab, graf
Artigo em Inglês | IBECS | ID: ibc-218464

RESUMO

Purpose: To evaluate the efficacy and safety of the low-power, high-frequency electrical current treatment administered by the Rexon-Eye device, in a cohort of patients affected by mixed-type dry eye disease (DED) of medium to severe level. Patients and methods: In this prospective, non-randomized, interventional clinical study, eighteen mixed type DED patients were treated. Treatment was a specific type of electrotherapy, Quantum Molecular Resonance (QMR®), administered by means of the Rexon-Eye® device (Resono Ophthalmic, Sandrigo, Italy) with a protocol of one 20-min session per week, for 4 weeks. Patients were examined at baseline and one month after the last treatment, utilizing the Ocular Surface Disease Index (OSDI) questionnaire and clinical signs: non-invasive tear break-up time (NIBUT), Oxford staining, meibum quality, meibography, meibomian gland expressibility, tear meniscus height (TMH), Schirmer's test, ocular inflammation expressed by MMP-9 concentration. Results: Subjective benefit in OSDI was reported (p = 0.013). Improvement was also observed in NIBUT (p < 0.001), Oxford staining (p = 0.002), expressible meibomian glands number (p = 0.001) and meibum quality (p < 0.001). A remarkable benefit was present in inflammation, as evidenced by the reduction of MMP-9 (p = 0.003). Changes, although not statistically significant, were also present in TMH (p = 0.076) and Schirmer's test (p = 0.675), whereas no change was observed in meibography score. No adverse event was reported. Conclusion: In this mixed-type DED patients’ cohort, Rexon-Eye proved to be effective and safe in improving subjective and objective ocular parameters, as well as capable to normalize inflammatory markers.(AU)


Assuntos
Humanos , Terapia por Estimulação Elétrica , Xeroftalmia , Plug Lacrimal , Oftalmopatias , Optometria , Estudos Prospectivos
10.
Oman J Ophthalmol ; 16(1): 165-169, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37007235

RESUMO

To present a case of anatomical success and visual improvement after the treatment of a long-standing foveal retinal detachment in a staphylomatous myopic eye with foveoschisis and macular hole. A 60-year-old woman with high myopia presented with foveoschisis and a lamellar macular hole in her right eye. After 2 years of follow-up without deterioration, her eye developed a full-thickness macular hole and a foveal retinal detachment which caused a severe reduction in visual acuity. However, the patient had no surgical treatment for her condition at that time. Vitrectomy was performed 2 years after the retinal detachment formation. Regardless of the longstanding detachment, anatomical success, and visual improvement were evident after the surgery. Despite a 2-year longstanding foveal detachment on a highly myopic eye with foveoschisis and macular hole, surgical repair could still be satisfactory.

11.
Medicina (Kaunas) ; 59(2)2023 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-36837582

RESUMO

Background and objectives: We aimed to evaluate the effects of the water drinking test (WDT) on several systemic and ocular parameters, including choroidal thickness, which was assessed through optical coherence tomography angiography (OCTA), in glaucoma suspects. Materials and Methods: A total of 40 eyes from 20 glaucoma suspects without any systemic or ocular diseases were included in this prospective observational study. All the participants undertook the WDT, which required the drinking of 1 L of table water in 5 min. The outcome measures included IOP, systolic and diastolic blood pressure (SBP and DBP), mean arterial pressure (MAP), mean ocular perfusion pressure (MOPP), ocular pulse amplitude (OPA), and subfoveal and peripapillary choroidal thickness, which were assessed at baseline and at four 15 min intervals after the WDT. Generalized least squares models and mixed model analyses that take into account repeated measurements were used to assess the changes over time of these parameters. Results: All the ocular and systemic parameters showed statistically significant changes at all time points compared to baseline apart from choroidal thickness. The peak changes were an IOP of 20.1 mmHg versus 17.3 mmHg at 45 min, an SBP of 137.6 mmHg versus 125 mmHg at 30 min, a DBP of 95.9 mmHg versus 85.7 mmHg at 15 min, and an MOP of 53.51 mmHg versus 48.89 mmHg at 15 min. Conclusions: Despite elevations in IOP and significant changes in all the assessed systemic parameters, the WDT was not associated with changes in choroidal thickness in glaucoma suspects.


Assuntos
Glaucoma de Ângulo Aberto , Pressão Intraocular , Humanos , Tonometria Ocular , Corioide , Água , Tomografia de Coerência Óptica
12.
Case Rep Ophthalmol ; 14(1): 23-28, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36644617

RESUMO

This report describes a case of a newly diagnosed 49-year-old HIV patient, who presented with decreased visual acuity and retinal lesions characterized by ischemia at the level of the deep retinal capillary plexus, documented with optical coherence tomography (OCT), OCT angiography, fluorescein angiography, and visual fields testing. These lesions closely resembled the morphologic and clinical characteristics of late paracentral acute middle maculopathy. The presence of these lesions suggests that HIV microangiopathy can potentially affect both superficial and deep retinal capillary plexuses.

13.
Ocul Immunol Inflamm ; 31(2): 449-454, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35113776

RESUMO

PURPOSE: To report a case of unilateral disc swelling as the only presentation of enterovirus meningitis in a 43-year-old male who presented with reduction in visual quality. METHODS: Vision was 20/20 unaided in both eyes and the only ocular finding was left optic disc edema accompanied by left relative afferent pupillary defect. Visual field examination revealed a generalized reduction in sensitivity, a paracentral scotoma and a superior and inferior arcuate defect. Apart from a marginally elevated white blood cell count, the evaluation for common diseases associated with unilateral disc swelling was negative. A comprehensive neurology and rheumatology assessment,the orbital, brain and cervical spine Magnetic Resonance Imaging (MRI), the chest and abdomen Computed Tomography (CT) and chest radiograph had no findings. However, the cerebrosipinal fluid (CSF) examination indicated the presence of enterovirus RNA. RESULTS: A diagnosis of enterovirus meningitis was established.Patient's general health was not affected and symptoms gradually settled, with no specific anti-enteroviral treatment. CONCLUSION: Only the CSF analysis provided interesting evidence of the site of the visual dysfunction.


Assuntos
Enterovirus , Meningite , Disco Óptico , Papiledema , Masculino , Humanos , Adulto , Papiledema/diagnóstico , Papiledema/etiologia , Papiledema/patologia , Disco Óptico/patologia , Nervo Óptico
14.
J Optom ; 16(2): 128-134, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35851496

RESUMO

PURPOSE: To evaluate the efficacy and safety of the low-power, high-frequency electrical current treatment administered by the Rexon-Eye device, in a cohort of patients affected by mixed-type dry eye disease (DED) of medium to severe level. PATIENTS AND METHODS: In this prospective, non-randomized, interventional clinical study, eighteen mixed type DED patients were treated. Treatment was a specific type of electrotherapy, Quantum Molecular Resonance (QMR®), administered by means of the Rexon-Eye® device (Resono Ophthalmic, Sandrigo, Italy) with a protocol of one 20-min session per week, for 4 weeks. Patients were examined at baseline and one month after the last treatment, utilizing the Ocular Surface Disease Index (OSDI) questionnaire and clinical signs: non-invasive tear break-up time (NIBUT), Oxford staining, meibum quality, meibography, meibomian gland expressibility, tear meniscus height (TMH), Schirmer's test, ocular inflammation expressed by MMP-9 concentration. RESULTS: Subjective benefit in OSDI was reported (p = 0.013). Improvement was also observed in NIBUT (p < 0.001), Oxford staining (p = 0.002), expressible meibomian glands number (p = 0.001) and meibum quality (p < 0.001). A remarkable benefit was present in inflammation, as evidenced by the reduction of MMP-9 (p = 0.003). Changes, although not statistically significant, were also present in TMH (p = 0.076) and Schirmer's test (p = 0.675), whereas no change was observed in meibography score. No adverse event was reported. CONCLUSION: In this mixed-type DED patients' cohort, Rexon-Eye proved to be effective and safe in improving subjective and objective ocular parameters, as well as capable to normalize inflammatory markers.


Assuntos
Síndromes do Olho Seco , Terapia por Estimulação Elétrica , Humanos , Síndromes do Olho Seco/tratamento farmacológico , Metaloproteinase 9 da Matriz/uso terapêutico , Glândulas Tarsais , Estudos Prospectivos , Lágrimas
15.
Int Ophthalmol ; 43(2): 363-370, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35864284

RESUMO

PURPOSE: To compare and analyze the interchangeability in measuring central corneal thickness (CCT) using ultrasonic pachymetry (USP, PACHMATE 2, DGH, Inc, Exton, PA, USA), non-contact specular microscopy (NCSM, CEM-530, Nidek CO, LTD, Gamagori, Japan) and a high-resolution Scheimpflug Camera (Pentacam HR, OCULUS, Wetzlar, Germany). METHODS: An observational, cross-sectional study was performed recruiting 216 volunteers, for a sample size of 216 eyes with no ocular abnormalities other than refractive errors. All subjects underwent pachymetric measurements obtained by USP, NCSM and Pentacam HR. Examinations were performed by the same examiner with USP always following the noncontact examinations. RESULTS: The mean CCT (± SD) was 560.30 ± 38.80 µm, 556.76 ± 36.83 µm and 547.31 ± 35.28 µm for USP, NCSM and Pentacam HR, respectively. The Bland-Altman analysis showed that the highest concordance was found between USP and NCSM, with differences between - 13.18 µm and 20.26 µm. For the differences between measurements obtained with Pentacam HR and USP, the differences at Bland-Altman plot were between - 28.25 and 13.57 µm. The lowest concordance was found for the CCT values measured with Pentacam HR and NCSM, with differences between - 25.67 and 6.86 µm. The intraclass correlation coefficient (ICC) between all pairs of measurements was between 0.979 and 0.987, suggesting that the mean measurements were strongly correlated. CONCLUSION: Measurements obtained with all three devices had high correlation. USP and NCSM were found in good agreement and high concordance, too. The above results indicate that these two devices are interchangeable in clinical practice. Pentacam HR may be a useful alternative for measuring CCT; however, it significantly underestimates CCT and cannot be used interchangeably with the other devices that we studied.


Assuntos
Córnea , Microscopia , Humanos , Microscopia/métodos , Estudos Transversais , Reprodutibilidade dos Testes , Paquimetria Corneana
16.
Artigo em Inglês | MEDLINE | ID: mdl-38476577

RESUMO

Background: Exposure to high-altitude conditions during flight or similar activities affects many aspects of visual function, which is critical not only for flight safety but for any altitude-related activity. We aimed to summarize the available literature pertaining to ocular changes during flight or equivalent short-term high-altitude exposure (e.g., hypobaric chamber, effortless ascent lasting ≤ 24 h) and to highlight future research priorities. Methods: Using the PubMed/MEDLINE and Web of Science/ISI Web of Knowledge databases with structured search syntax, we conducted a systematic review of the literature spanning a 40-year period (January 1, 1983, to October 10, 2023). Articles pertaining to ocular changes during flight or flight-equivalent exposure to altitude were retrieved. The reference lists of retrieved studies were also searched, and citations of these references were included in the results. Results: Of 875 relevant PubMed and ISI publications, 122 qualified for inclusion and 20 more were retrieved from the reference lists of initially selected records, for a total of 142 articles. Reported anterior segment changes included deterioration in tear film stability and increased dry eye incidence, increased corneal thickness, discomfort and bubble formation in contact lens users, refraction changes in individuals with prior refractive surgery, decreased intraocular pressure, and alterations in pupillary reaction, contrast sensitivity, and visual fields. Photoreceptor-visual pathway changes included alterations in both photoreceptors and neuro-transduction, as evidenced in dark adaptation, macular recovery time, reduction in visual field sensitivity, and optic neuritis (likely an element of decompression sickness). Retinochoroidal changes included increases in retinal vessel caliber, retinal blood flow, and choroidal thickness; central serous chorioretinopathy; and retinal vascular events (non-arteritic ischemic optic neuropathy, high-altitude retinopathy, and retinal vein occlusion). Conclusions: The effect of short-term high-altitude exposure on the eye is, in itself, a difficult area to study. Although serious impairment of visual acuity appears to be rare, ocular changes, including tear film stability, contact lens wear, central corneal thickness, intraocular pressure, contrast sensitivity, stability of refractive surgeries, retinal vessels, visual fields, and macula recovery time, should be considered in civilian aviators. Our report provides guidance to climbers and lowlanders traveling to altitude if they have pre-existing ocular conditions or if they experience visual symptoms while at altitude. However, key outcomes have been contradictory and comprehensive studies are scarce, especially those pertaining to the choroid and retina. Such studies could not only deepen our understanding of high-altitude ocular pathophysiology, but could also offer valuable information and treatment possibilities for a constellation of other vision-threatening diseases.

17.
Saudi J Ophthalmol ; 36(2): 207-212, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36211308

RESUMO

PURPOSE: To evaluate the long-term visual function and patient satisfaction in patients implanted bilaterally with the same type of multifocal intraocular lens (MIOL), using either a 2.2 mm small corneal incision with bimanual irrigation/aspiration (I/A) or a conventional 2.75 mm incision with coaxial I/A. METHODS: Prospective nonrandomized study including 100 eyes of 50 patients who underwent bilateral implantation of ReSTOR SN6AD1 through a 2.2 mm or 2.75 mm corneal incision. Outcomes included visual function measures (near, intermediate, and distance visual acuity [VA]), achievement of targeted refraction and postoperative astigmatism. Patient satisfaction was evaluated using a subjective questionnaire. RESULTS: Three and 12 months postoperatively, distance uncorrected best VA (UBVA) was 0.98 ± 0.07, UBVA at 30 cm was J1 in 100% of cases and UBVA at 60 cm was J3 in 72% of cases. Targeted refraction was achieved in 84% of cases and postoperative astigmatism was -0.4 ± 0.3 diopters. There was no statistically significant difference in UBVA in all distances, targeted refraction and postoperative astigmatism between the small-incision bimanual and the conventional coaxial group. Sixty percent of the patients were satisfied, 30% were very satisfied and 10% declared that the result did not meet their expectations. Three out of 5 nonsatisfied patients had an angle kappa of 4° and the MIOL was not well-centered. CONCLUSION: An incision size of 2.2 mm compared to 2.75 mm, did not appear to result in less surgically induced astigmatism after the implantation of a MIOL. SN6AD1 is a reliable MIOL choice for spectacle independence. Good preoperative patient selection is of crucial importance for the outcome in MIOLs.

18.
Saudi J Ophthalmol ; 36(2): 229-236, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36211320

RESUMO

PURPOSE: The purpose of the study is to evaluate the comparability of corneal power measurements, anterior chamber depth (ACD), and white-to-white (WTW) distance between a high-resolution Scheimpflug-based tomography (Pentacam HR; Oculus GmbH, Wetzlar, Germany) and a swept-source optical biometry, IOL Master 700; Carl Zeiss Meditec AG, Jena, Germany) in patients having undergone a myopic refractive surgery. METHODS: This prospective, interinstrument reliability analysis included 31 individuals with a previous myopic laser refractive correction. Standard keratometry and total keratometry (TK) of the flattest and steepest axis of the IOL Master 700 were compared with standard keratometry (simulated keratometry [SimK]), true net power (TNP), equivalent keratometer readings (EKR), and total corneal refractive power of the Pentacam. The Bland-Altman analysis evaluated the agreement between the measurements of both devices. A paired t-test was performed to compare the mean values of the variables obtained by the two devices. RESULTS: Mean age of the participants was 31.87 ± 13.17 years. Ten patients (32.3%) had undergone laser in situ keratomileusis surgery, and 21 (67.7%) had undergone photorefractive keratectomy surgery. The two devices generated statistically significant differences in almost all the comparisons between their corneal keratometry values, ACD, and WTW. The two devices agreed in some of the flat axis values and more specifically on SimK1 and K1, EKR K1 along 1 mm-zone and K1, as well as on the comparison between the EKR keratometry values along 1, 2, and 3 mm-zone with their corresponding TKs. CONCLUSION: IOL Master 700 and Pentacam HR do not show good concordance and cannot be used interchangeably when measuring keratometry values in postrefractive eyes, rendering the IOL power calculation in postrefractive eyes really challenging.

19.
Int Ophthalmol ; 42(10): 3017-3025, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35394587

RESUMO

PURPOSE: To evaluate preoperatively dry eye disease (DED) in patients with pathological Tear Break Up Time (TBUT), utilising subjective Ocular Surface Disease Index (OSDI) with its subcategories and objective Keratograph 5M characteristics. METHODS: Fifty-four cataract patients were included in this prospective study having a screening slit lamp TBUT of less than 10 s and more or equal to 5 s. Subjective evaluation of DED was performed with OSDI questionnaire and objective evaluation with Keratograph 5M. Tear Meniscus Height (TMH), bulbar and limbal redness and meibography grade were evaluated. Further analysis of OSDI subcategories, Visual Function Related (VFR), Ocular Symptoms related (OS) and Environmental Triggered (ET), was performed with linear and logistic multivariate regression models. Age, gender and logMAR visual acuity (VA) were also included in our models. RESULTS: Following the initial TBUT screening we identified 27(50%) normal and 27(50%) dry eye patients, using OSDI questionnaire. There was no statistical difference in TMH (p = 0.64), bulbar redness (p = 0.54), limbal redness (p = 0.72) and meibography grade (p = 0.25), between normal and dry eye OSDI group. In our regression analysis, average logMAR VA was highly associated with a higher total OSDI score (p < 0.001) and with a higher OSDI-VFR score (p < 0.001). Female gender was associated with a higher OSDI-ET score (p = 0.03). Multivariate logistic regression models were performed by sorting patients into 2 categories of normal and dry eye group according to their total OSDI,OSDI-VRF,OSDI-OS and OSDI-ET score. An increase in logMAR VA increased the odds of having abnormal total OSDI score (p = 0.007) and OSDI-VFR score (p = 0.006). Females had increased odds of having abnormal OSDI-ET score (p = 0.044). CONCLUSIONS: Clinicians should be aware of OSDI limitations when screening cataract patients for dry eyes, as there is high correlation with VA. Female patients were more susceptible to environmental factors. Keratograph results should be interpreted with caution when they are evaluated in conjunction with OSDI during preoperative assessment of DED in cataract patients.


Assuntos
Catarata , Síndromes do Olho Seco , Síndromes do Olho Seco/diagnóstico , Síndromes do Olho Seco/etiologia , Feminino , Humanos , Estudos Prospectivos , Inquéritos e Questionários , Lágrimas
20.
Ther Adv Ophthalmol ; 14: 25158414211063283, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35387236

RESUMO

Background: Cataract surgery in keratoconic patients is challenging because of the corneal distortion, which can lead to inaccurate keratometry readings. This study is a comparison of the accuracy of keratometry readings by two types of devices in a tertiary hospital. Purpose: To evaluate the comparability of corneal power measurements, anterior chamber depth (ACD), and white-to-white (WTW) distance between Scheimpflug-based tomography (Pentacam AXL; OCULUS GmbH, Wetzlar, Germany) and swept-source optical biometry (IOLMaster 700; Carl Zeiss Meditec AG, Jena, Germany) in patients with keratoconus. Methods: This pilot, prospective, interinstrument reliability study included 30 keratoconic eyes of 15 individuals who had not undergone any kind of corneal surgery. Standard K and total refractive power (TK®) of the flattest and steepest axes of the IOLMaster 700 were compared with the standard keratometry (SimK), true net power (TNP), equivalent keratometer readings (EKR), and total corneal refractive power (TCRP) of the Pentacam. The Bland-Altman analysis was used to evaluate the agreement between the measurements of both devices. The paired-samples t-test and the Wilcoxon signed-rank test were performed to compare the mean values of the variables obtained with the devices. Results: The K1 value of the IOLMaster 700 was significantly higher from EKR K1 along the 3-mm (mean difference: 0.79 diopters, p = 0.01), 4-mm (mean difference: 1.01 D, p = 0.01), and 4.5-mm zones (mean difference: 1.20 D, p = 0.01) and TNP K1 along the 3-mm (mean difference: 0.88 D, p < 0.001) and 4-mm zones (mean difference: 0.97 D, p < 0.001). The TK1 value was significantly higher from EKR K1 along the 2-mm (mean difference: 0.42 D, p = 0.04), 3-mm (mean difference: 0.83 D, p = 0.003), 4-mm (mean difference: 1.05 D, p = 0.004), and 4.5-mm zones (mean difference: 1.24 D, p = 0.005) and TNP K1 along the 3-mm (mean difference: 0.92 D, p < 0.001) and 4-mm zones (mean difference: 1.01 D, p < 0.001). The K2 value of the IOLMaster 700 was significantly higher from TK2 (mean difference: 0.11 D, p = 0.04) and all the corresponding variables of the Pentacam device. The TK2 value was significantly higher from all the corresponding variables of the Pentacam device. The Pentacam also yielded significantly lower values for the WTW distance (mean difference: 0.31 mm, p < 0.001) and no significant difference in terms of ACD values (p = 0.9). Conclusion: The IOLMaster measured significantly greater keratometry readings in the steep axis for all the variables studied. The keratometry and WTW measurements of the investigated devices cannot be used interchangeably in keratoconus.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...